This thesis combines field and laboratory measurements with three dimensional (3D) finite element analysis (FEM) to demonstrate the use of Time Domain Reflectometry (TDR) cable-grout composites to measure localized shearing in soft soil. Past field installations of TDR cable-grout composites in rock have lead to its widespread use in the...
This paper describes qualification of devices to measure sub micro-meter changes in crack width, which is the basis of autonomous crack monitoring for control of blasting vibrations. Performance of LVDT, eddy current and potentiometer sensors to monitor long-term and transient displacements will be described. Potentiometers are attractive for wireless measurement,...
This thesis consists of the data and analysis of structural responses for two different studies: the Office of Surface Mining (OSM) study of the velocity response of “atypical” residential structures and the Autonomous Crack Monitoring (ACM) study. The main basis of this thesis was to do additional analysis on a...
This appendix synthesizes micrometer changes in crack width in response to both long term (environmental) and transient (blast vibration) of four of the structures in the main body. The appendix begins with a description of the genesis of the study and instruments employed. Response of the distressed wood-framed structure in...
Autonomous Crack Measurement (ACM) facilitates simultaneous measurement of crack response to environmental changes and vibrations produced by various construction activities. Dual-purpose crack displacement sensors measure crack response, while the vibration environment is defined by standard seismological transducers and the weather environment is defined as changes in temperature and humidity. This...
Cosmetic cracks are very common in structures, and most of the time they remain unnoticed and do not decrease the structural integrity. Although these cracks are unremarkable and barely noticeable, occupants become concerned about these cracks when construction occurs nearby. In order to investigate the true nature of these cracks,...
Crack and structural response to construction trench blasting was measured in a woodframe house with a stucco exterior. Blasts at distances between 232 m to 368 m produced peak particle velocities (PPV) and air blast over pressures (AB) of 9 mm/sec and 0.02 kPa (123 dB), respectively. Structural response velocities...
A unique judicial opportunity allowed measurement of the response of three cracks in residential structure to blasting for underground aggregate mining. Instrumented cracks were located in the interior basement CMU mortar and upstairs dry wall as well as exterior brick work. The dynamic environment was unusual. Even though the blasting...
Micro-meter dynamic crack responses in a two story structure to rock blasting- and wind gust- excitation are compared to those induced by long term climatological effects. These measurements substantiate the conservancy of the 12.5 mm/s (0.5 in./s) blasting vibration control to protect residential structures against cracking. The test structure was...
This paper describes the technology and methods deployed in the continuous autonomous remote monitoring of cracks in interior and exterior walls of a residence near a limestone quarry. The object is to quantitatively compare crack response to blast-induced ground motion to that induced by diurnal temperature changes, weather fronts, and...